Polymers in Hydrogen Service
A Practical Guide for Engineers

Know what hydrogen does to your seals – before the field tells you.

Your seal meets every value on the datasheet. That is no guarantee it will work in hydrogen at 70 MPa, at −40 °C and through repeated rapid decompression. This book shows design engineers how to size, select and test polymer parts for exactly that load case.

Available January 2027 · Single licence €79
Format
E-book (PDF)
Language
English
Chapters
10
Figures
25
Print-ready templates
4

A datasheet can rule a compound out. It can never rule one in.

Datasheet values are measured in air, at room temperature, on a relaxed and gas-free sample. A seal in hydrogen service works compressed, saturated with gas and cold. The table is taken from Chapter 5.

What the datasheet showsWhat hydrogen service asks
Hardness, tensile strength, elongation in airDo these hold while hydrogen is dissolved?
Compression set at constant temperatureDoes the seal keep its force at −40 °C under pressure?
Swelling in reference oilsHow much does it swell in H₂, and does it fit the gland?
One-time property valuesHow does damage build up over thousands of decompressions?
“H₂-compatible” labelAt which pressure, temperature, rate and cycle count?

Written for the engineer who signs the drawing

Seals, hoses, liners, pipes and valve seats for hydrogen. After reading, you can do the following yourself.

  1. 01
    Define the duty cycle in numbers. Pressure, temperature range, venting rate and cycle count over the design life, on one sheet.
  2. 02
    Size the gland for a seal that swells. Gland fill, extrusion gap, squeeze at the cold end and cross-section, each with the reason behind it.
  3. 03
    Judge an RGD test report. Check gas, pressure, hold time, decompression rate and cycles against your own load case.
  4. 04
    Question an “H₂-compatible” claim. Fourteen questions to send to a supplier before a compound goes on your shortlist.
  5. 05
    Scale the test effort to the risk. Three risk levels with a minimum programme for each, and the triggers that make a release invalid.

Contents

1
Why polymers matter in the hydrogen economy
Where they are used and why oil-and-gas experience only partly transfers
2
Fundamentals of hydrogen transport in polymers
Solubility, diffusion, permeation; temperature, pressure, multilayer walls
3
Damage mechanisms
Rapid gas decompression, swelling, ageing, wear, cold, interfaces, defects
4
Material families
Elastomers, thermoplastics, fillers, network and the PFAS question
5
Fundamentals of testing
Screening, characterisation, qualification; standards; ex-situ vs. in-situ
6
Test methods and what each adds
Hollow specimens, fracture mechanics, RGD and permeation testing
7
From datasheet to RGD-proven material
The five-step path, a worked O-ring example, how much testing is enough
8
Real service exposure
Lessons from refuelling stations and three case studies from the field
9
Design and material-selection guidelines
Ten rules of thumb, selection checklist, gland design for hydrogen O-rings
10
Outlook and open research questions
Lifetime prediction, monitoring, liquid hydrogen, sustainable materials
A
Template: duty-cycle definition sheet
Fill in before any material is selected
B
Template: material selection checklist
Sixteen checks from material evidence to release decision
C
Template: RGD test report review
Reported test conditions against your duty cycle
D
Template: supplier datasheet review
The questions behind every “H₂-compatible” claim
From Chapter 9.4

The gland decides whether a good compound survives

An O-ring with good decompression resistance can still fail when the groove leaves no room for swelling. Three of the six gland checks in the book:

CheckWhy it matters in hydrogenTypical action
Gland fillHydrogen swells the seal under pressure; a full groove forces material into the gapSize the groove for the swollen volume at maximum pressure and temperature, not the dry seal
Extrusion gapAt 70–87.5 MPa even small clearances extrude a swollen, softened sealMinimise clearance; add back-up rings on the low-pressure side
Squeeze at the cold endContact stress falls as the rubber stiffens and shrinks near −40 °CVerify squeeze and sealing at minimum temperature, under pressure

About the author

Portrait of Dr. Bernd Schrittesser

Dr. Bernd Schrittesser studied polymer engineering at Montanuniversität Leoben and wrote his doctoral thesis on the performance of elastomers for high-pressure applications.

He spent more than eleven years at the Polymer Competence Center Leoben, most recently heading Elastomer Technology and Process Optimization. Since 2023 he has led an independent laboratory in Austria that specialises in hydrogen safety and materials testing under high pressure. His research covers rapid gas decompression, hydrogen permeation modelling and in-situ testing under hydrogen.

He is an Austrian delegate to ISO/TC 197, the ISO technical committee for hydrogen technologies, and contributes to the German Standardization Roadmap for Hydrogen Technologies, where he co-heads the sub-working committee on materials and heads the working group on composites and plastics.

This book reflects the author’s personal views. It is not endorsed by ISO, DIN or Austrian Standards.

Polymers in Hydrogen Service

The complete guide as a PDF, including Templates A to D as one-page forms to print and fill in. Available January 2027.

Single licence: €79 incl. VAT
Company licence, up to 10 readers: €349
Larger teams: on request
Notify me at launch
One email when the book is out. Or write to info@polymers-in-hydrogen.com