Know what hydrogen does to your seals – before the field tells you.
Your seal meets every value on the datasheet. That is no guarantee it will work in hydrogen at 70 MPa, at −40 °C and through repeated rapid decompression. This book shows design engineers how to size, select and test polymer parts for exactly that load case.
- Format
- E-book (PDF)
- Language
- English
- Chapters
- 10
- Figures
- 25
- Print-ready templates
- 4
A datasheet can rule a compound out. It can never rule one in.
Datasheet values are measured in air, at room temperature, on a relaxed and gas-free sample. A seal in hydrogen service works compressed, saturated with gas and cold. The table is taken from Chapter 5.
| What the datasheet shows | What hydrogen service asks |
|---|---|
| Hardness, tensile strength, elongation in air | Do these hold while hydrogen is dissolved? |
| Compression set at constant temperature | Does the seal keep its force at −40 °C under pressure? |
| Swelling in reference oils | How much does it swell in H₂, and does it fit the gland? |
| One-time property values | How does damage build up over thousands of decompressions? |
| “H₂-compatible” label | At which pressure, temperature, rate and cycle count? |
Written for the engineer who signs the drawing
Seals, hoses, liners, pipes and valve seats for hydrogen. After reading, you can do the following yourself.
- 01Define the duty cycle in numbers. Pressure, temperature range, venting rate and cycle count over the design life, on one sheet.
- 02Size the gland for a seal that swells. Gland fill, extrusion gap, squeeze at the cold end and cross-section, each with the reason behind it.
- 03Judge an RGD test report. Check gas, pressure, hold time, decompression rate and cycles against your own load case.
- 04Question an “H₂-compatible” claim. Fourteen questions to send to a supplier before a compound goes on your shortlist.
- 05Scale the test effort to the risk. Three risk levels with a minimum programme for each, and the triggers that make a release invalid.
Contents
The gland decides whether a good compound survives
An O-ring with good decompression resistance can still fail when the groove leaves no room for swelling. Three of the six gland checks in the book:
| Check | Why it matters in hydrogen | Typical action |
|---|---|---|
| Gland fill | Hydrogen swells the seal under pressure; a full groove forces material into the gap | Size the groove for the swollen volume at maximum pressure and temperature, not the dry seal |
| Extrusion gap | At 70–87.5 MPa even small clearances extrude a swollen, softened seal | Minimise clearance; add back-up rings on the low-pressure side |
| Squeeze at the cold end | Contact stress falls as the rubber stiffens and shrinks near −40 °C | Verify squeeze and sealing at minimum temperature, under pressure |
Polymers in Hydrogen Service